<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Unique Aqua Systems &#38; Chemical Industruies &#187; Chemical Water Treatment Division</title>
	<atom:link href="https://uniqueaquasystems.com/category/chemical-division/feed/" rel="self" type="application/rss+xml" />
	<link>https://uniqueaquasystems.com</link>
	<description>Water Treatment Company</description>
	<lastBuildDate>Wed, 08 Oct 2014 17:52:24 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.0.38</generator>
	<item>
		<title>UNI-TREAT® Sugar Process Chemicals</title>
		<link>https://uniqueaquasystems.com/uni-treat-sugar-process-chemicals/</link>
		<comments>https://uniqueaquasystems.com/uni-treat-sugar-process-chemicals/#comments</comments>
		<pubDate>Thu, 14 Aug 2014 17:23:48 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=386</guid>
		<description><![CDATA[We are also engaged in manufacturing Sugar Process Chemicals of high quality.]]></description>
				<content:encoded><![CDATA[<div class="info_div_out">
<p>We are also engaged in manufacturing Sugar Process Chemicals of high quality.<img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/sugar_factory-1024x443.jpg" alt="sugar_factory" width="474" height="205" class="alignnone size-large wp-image-442 pull-right thumb img_space_left" /></p>
<p><span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Sugar Process Chemicals</span></span></p>
<div class="info_product_div">
<ol class="para_line_sub">
<li>pH Booster – Spray Pond Water.</li>
<li>Scale Inhibitor Evaporator Anti-scalant, Additive For Evaporator Bodies To Inhibit Carbonate, Sulphate And </li>
<li>Silica Scale From Cane Juice.</li>
<li>Viscosity Reducer Pan Boiling Aid to Reduce Viscosity Of Massecuite.</li>
<li>Sugar Extractor -Additive In Imbibition Water to Extract More Sugar From Bagasse.</li>
<li>Bagasse – Fire Mate (Additive to Improve the Bagasse).</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/uni-treat-sugar-process-chemicals/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>UNI-TREAT® Fire Side System Chemicals</title>
		<link>https://uniqueaquasystems.com/uni-treat-fire-side-system-chemicals/</link>
		<comments>https://uniqueaquasystems.com/uni-treat-fire-side-system-chemicals/#comments</comments>
		<pubDate>Thu, 14 Aug 2014 17:18:36 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=384</guid>
		<description><![CDATA[Impurities in fuels can cause deposit formation and fire side metal corrosion. The most severe problems are generally found in combustion fouling and corrosion. UNI-TREAT® fire side chemicals are used to control fouling by elevating the melting points of the deposits by physically diluting deposits, or by providing a shear plane to assist in removal [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="info_div_out">
<p><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/rev_osmosis3.jpg" alt="rev_osmosis3" width="353" height="192" class="alignnone size-full wp-image-289 pull-right thumb img_space_left" />Impurities in fuels can cause deposit formation and fire side metal corrosion. The most severe problems are generally found in combustion fouling and corrosion. UNI-TREAT<SUP>®</SUP> fire side chemicals are used to control fouling by elevating the melting points of the deposits by physically diluting deposits, or by providing a shear plane to assist in removal by soot blowing.</p>
<p><span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Fire Side System Chemicals</span></span>
<div class="info_product_div">
<ol class="para_line_sub">
<li>Multi purpose Solid Fuel Additive For Wood, Coal etc.</li>
<li>Furnace Post Treatment, Clear Compound ( 0Canister set)</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/uni-treat-fire-side-system-chemicals/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>UNI-TREAT® Speciality Chemicals</title>
		<link>https://uniqueaquasystems.com/uni-treat-speciality-chemicals/</link>
		<comments>https://uniqueaquasystems.com/uni-treat-speciality-chemicals/#comments</comments>
		<pubDate>Thu, 14 Aug 2014 17:16:21 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=382</guid>
		<description><![CDATA[We manufacture and trade different types of specialty chemicals.]]></description>
				<content:encoded><![CDATA[<div class="info_div_out">
We manufacture and trade different types of specialty chemicals.
<div class="img_div_out pull-right"><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/pecialitys-chemical-300x245.jpg" alt="speciality-chemical" width="300" height="245" class="alignnone size-medium wp-image-441 pull-right img_space_left thumb" /></div>
<p><span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Speciality Chemicals</span></span></p>
<div class="info_product_div">
<ol class="para_line_sub">
<li>Potable Water Corrosion Inhibitor</li>
<li>Defoamer</li>
<li>Oil Dispersant</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/uni-treat-speciality-chemicals/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Reverse Osmosis Treatment</title>
		<link>https://uniqueaquasystems.com/reverse-osmosis-treatment/</link>
		<comments>https://uniqueaquasystems.com/reverse-osmosis-treatment/#comments</comments>
		<pubDate>Mon, 04 Aug 2014 18:24:18 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=286</guid>
		<description><![CDATA[Scaling And Fouling In Membranes &#8211; Membrane fouling is a process where solute or particles deposit onto a membrane surface or into membrane pores in a way that degrades the membrane’s performance. It is a major obstacle to the widespread use of this technology. Membrane fouling can cause severe flux decline and affect the quality [&#8230;]]]></description>
				<content:encoded><![CDATA[<p><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/rev_osmosis2.jpg" alt="rev_osmosis2" width="159" height="111" class="alignnone size-full wp-image-288 pull-right img_space_left thumb" /><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/rev_osmosis1.jpg" alt="rev_osmosis1" width="158" height="111" class="alignnone size-full wp-image-287 pull-right img_space_left thumb" />Scaling And Fouling In Membranes &#8211; Membrane fouling is a process where solute or particles deposit onto a membrane surface or into membrane pores in a way that degrades the membrane’s performance. It is a major obstacle to the widespread use of this technology. Membrane fouling can cause severe flux decline and affect the quality of the water produced. Severe fouling may require intense chemical cleaning or membrane replacement.</p>
<div class="info_div_out">
<span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> R. O. Treatment Chemicals</span></span></p>
<div class="info_product_div">
<ol class="para_line_sub">
<li>UNI-TREAT<SUP>®</SUP> R.O. Anti-scalents</li>
<li>UNI-TREAT<SUP>®</SUP> R.O. Membrane Cleaners</li>
<li>UNI-TREAT<SUP>®</SUP> R.O. Membrane Bio-fouling Cleaners</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/reverse-osmosis-treatment/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Descaling Products</title>
		<link>https://uniqueaquasystems.com/descaling-products/</link>
		<comments>https://uniqueaquasystems.com/descaling-products/#comments</comments>
		<pubDate>Mon, 04 Aug 2014 18:10:54 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=276</guid>
		<description><![CDATA[After Before Scale formation is a hard layer of various dissolved salts on heat exchange surfaces due to dissolved salts of water, which causes various problems such as clogging, lower heat transfer, loss of metal and equipment. This scale is to be removed to achieve proper performance of machines and equipments. The descaling compound is [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="img_compare pull-right img_space_left"><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/descale1b.jpg" alt="descale1b" width="111" height="120" class="alignnone size-full wp-image-278 thumb" /><br/><br/><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/descale2b.jpg" alt="descale2b" width="111" height="120" class="alignnone size-full wp-image-280 thumb" /><br/>After</div>
<div class="img_compare pull-right img_space_left"><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/descale1a.jpg" alt="descale1a" width="111" height="120" class="alignnone size-full wp-image-277 thumb" /><br/><br/><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/descale2a.jpg" alt="descale2a" width="111" height="120" class="alignnone size-full wp-image-279 thumb" /><br/>Before</div>
<p>Scale formation is a hard layer of various dissolved salts on heat exchange surfaces due to dissolved salts of water, which causes various problems such as clogging, lower heat transfer, loss of metal and equipment. This scale is to be removed to achieve proper performance of machines and equipments. The descaling compound is a combination chemical which removes the hard scaling.</p>
<div class="info_div_out">
<span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Descaling Chemicals</span></span>
<div class="info_product_div">
<ol class="para_line_sub">
<li>UNI-TREAT<sup>®</sup> Descaling liquid compound (For MS surfaces and Hard Scales)</li>
<li>UNI-TREAT<sup>®</sup> Powder compound for soft metal, such as Copper and Stainless Steel</li>
<li>UNI-TREAT<sup>®</sup> alkaline descaling Chemical</li>
<li>UNI-TREAT<sup>®</sup> Silica descalent</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/descaling-products/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Boiler Water Treatment</title>
		<link>https://uniqueaquasystems.com/boiler-water-treatment/</link>
		<comments>https://uniqueaquasystems.com/boiler-water-treatment/#comments</comments>
		<pubDate>Mon, 04 Aug 2014 17:58:50 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=271</guid>
		<description><![CDATA[Boilers are important equipments used in industrial processes. Boiler water quality is of prime importance in order to obtain maximum output without any breakdowns. Therefore Pretreatment and chemical treatment of the water is very important to prevent scale &#038; corrosion in boilers. Regular boiler water conditioning is essential for a trouble free and safe boiler [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="img_div_out pull-right"><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/boiler1.jpg" alt="boiler1" width="111" height="111" class="alignnone size-full wp-image-272 pull-right img_space_left thumb" /><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/boiler2.jpg" alt="boiler2" width="120" height="111" class="alignnone size-medium wp-image-273 pull-right img_space_left thumb" /><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/08/boiler_plant_sm-300x240.jpg" alt="boiler_plant_sm" width="300" height="240" class="alignnone size-medium wp-image-438 pull-right img_space_left thumb" /></div>
<p>Boilers are important equipments used in industrial processes. Boiler water quality is of prime importance in order to obtain maximum output without any breakdowns. Therefore Pretreatment and chemical treatment of the water is very important to prevent scale &#038; corrosion in boilers. Regular boiler water conditioning is essential for a trouble free and safe boiler operation. We provide effective formulations for improved boiler water treatment operations.</p>
<div class="info_div_out">
<span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Boiler Water Treatment Chemical Solutions</span></span>
<div class="info_product_div">
<ol class="para_line_sub">
<li>UNI-TREAT<sup>®</sup> Softening Agent, anti-scalant</li>
<li>UNI-TREAT<sup>®</sup> Polymeric Sludge conditioner</li>
<li>UNI-TREAT<sup>®</sup> Instant Oxygen Scavenger</li>
<li>UNI-TREAT<sup>®</sup> Corrosion Control agents, Neutralizing agents</li>
<li>UNI-TREAT<sup>®</sup> Multi-purpose Chemical (Scale, Alkinity Builder and Oxygen Scavenger)</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/boiler-water-treatment/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Closed Loop Cooling Systems (Chillers)</title>
		<link>https://uniqueaquasystems.com/closed-loop-cooling-systems-chillers/</link>
		<comments>https://uniqueaquasystems.com/closed-loop-cooling-systems-chillers/#comments</comments>
		<pubDate>Sun, 13 Jul 2014 18:36:43 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=34</guid>
		<description><![CDATA[In a Closed Loop Cooling Systems, water circulates in a closed cycle and is subjected to alternate cooling and heating without air contact. Heat, absorbed by the water in the closed system, is normally transferred by a Water-to-refrigerant or Water exchanger to the recirculating water of an open recirculating system, from which the heat is [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="pull-right img_div_out"><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/chiller1.jpg" alt="chiller1" width="240" height="154" class="alignnone size-full wp-image-267 pull-right img_space_left thumb" /><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/chilling-plant-300x225.jpg" alt="chilling-plant" width="240" height="" class="alignnone size-medium wp-image-435 pull-right img_space_left thumb" /></div>
<p>In a Closed Loop Cooling Systems, water circulates in a closed cycle and is subjected to alternate cooling and heating without air contact. Heat, absorbed by the water in the closed system, is normally transferred by a Water-to-refrigerant or Water exchanger to the recirculating water of an open recirculating system, from which the heat is lost to atmosphere. The more common problem to either heating or cooling closed loops is corrosion.</p>
<div class="info_div_out">
<span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Close Loop Water Treatment Chemical Solutions</span></span>
<div class="info_product_div">
<ol class="para_line_sub">
<li>UNI-TREAT<sup>®</sup> Close Loop Corrosion Inhibitors</li>
</ol>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://uniqueaquasystems.com/closed-loop-cooling-systems-chillers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Open Loop Cooling Water Systems (Cooling Towers)</title>
		<link>https://uniqueaquasystems.com/open-loop-cooling-water-systems/</link>
		<comments>https://uniqueaquasystems.com/open-loop-cooling-water-systems/#comments</comments>
		<pubDate>Sun, 06 Jul 2014 09:07:54 +0000</pubDate>
		<dc:creator><![CDATA[uniqadminuser]]></dc:creator>
				<category><![CDATA[Chemical Water Treatment Division]]></category>

		<guid isPermaLink="false">http://?p=1</guid>
		<description><![CDATA[Open to the atmosphere; contains the Cooling Tower. Open Loop Cooling Water Systems is a heat rejection device which extracts waste heat to the atmosphere through the cooling of a water stream to a lower temperature. From a  water treatment perspective, the most critical and challenging  portion of the system to treat with cooling tower [&#8230;]]]></description>
				<content:encoded><![CDATA[<p><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/cooling_tower1-300x202.jpg" alt="cooling_tower1" width="300" height="202" class="alignnone size-medium wp-image-434 pull-right thumb img_space_left" />Open to the atmosphere; contains the Cooling Tower. Open Loop Cooling Water Systems is a heat rejection device which extracts waste heat to the atmosphere through the cooling of a water stream to a lower temperature. From a  water treatment perspective, the most critical and challenging  portion of the system to treat with cooling tower water treatment  chemicals is the Open Loop. Here water is cascaded over the cooling  tower, providing for greater surface area that allows for air passing through the water via the tower fan to absorb heat from the water and exhaust it out of the tower. Since water is being constantly lost  by evaporation, these systems require large amounts of make-up water to remain in balance. In the Open Loop, there are four  significant problem areas to be addressed with cooling tower water treatment chemicals:</p>
<div class="info_div_out">
<span class="sub_heading">Scale</span><img class="alignnone wp-image-236 size-full pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/scale2.jpg" alt="scale2" width="130" height="110" /> <img class="alignnone wp-image-235 size-full pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/scale1.jpg" alt="scale1" width="130" height="110" />Because water is continually being lost by evaporation, fresh water has to be added.  With this water come certain impurities – hardness, alkalinity, silica, to name a few. As the water is evaporated, the impurities stay behind,  increasing the potential for the system to begin forming scale deposits.
</div>
<div class="info_div_out">
<span class="sub_heading">Corrosion</span><img class="alignnone size-full wp-image-249 pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/Corrosion1.jpg" alt="Corrosion1" width="162" height="111" /><img class="alignnone size-full wp-image-250 pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/Corrosion2.jpg" alt="Corrosion2" width="109" height="111" />Anytime water and metal come in contact, there is going to be corrosion. How well the water treatment professional minimizes that corrosion is a measure of the water treatment program’s success.
</div>
<div class="info_div_out">
<span class="sub_heading">Fouling</span><img src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/fouling1.jpg" alt="fouling1" width="131" height="110" class="alignnone size-full wp-image-253 pull-left img_space thumb" /> <img class="alignnone size-full wp-image-254 pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/fouling2.jpg" alt="fouling2" width="131" height="110" />The effect of airborne contaminants (airborne dust, dirt) that are subjected to the system by movement of the air through the water and to a lesser degree by particles falling directly into the tower (leaves, bird droppings).
</div>
<div class="info_div_out">
<span class="sub_heading">Microbiological Contaminants</span><img class="alignnone size-full wp-image-255 pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/microbiological1.jpg" alt="microbiological1" width="131" height="111" /><img class="alignnone size-full wp-image-256 pull-left img_space thumb" src="http://uniqueaquasystems.com/wp-content/uploads/2014/07/microbiological2.jpg" alt="microbiological2" width="131" height="111" />A layer of dead or alive microbiological growths (algae, fungi, yeasts, molds, &#038; bacteria) that can cause corrosion, lead to increased scaling, provide a means to trap foulant materials &#038; can cause excessive energy consumption if they build films on the heat exchange components. A microbio film of 1/64” can cause up to a 30% increase in electrical demand.
</div>
<div class="info_div_out">
<span class="sub_heading_blue"><span class="main">UNI-TREAT<SUP>®</SUP> Series Of Cooling Water Treatment Chemical Solutions</span></span>
<div class="info_product_div">
<ol class="para_line_sub">
<li>UNI-TREAT<sup>®</sup> Non-oxydising And Oxydising Biocides </li>
<li>UNI-TREAT<sup>®</sup> Dispersants</li>
<li>UNI-TREAT<sup>®</sup> Scale Inhibitor ( Carbonate, Sulphate , Silica Inhibitor) </li>
<li>UNI-TREAT<sup>®</sup> Corrosion Inhibitors</li>
<li>UNI-TREAT<sup>®</sup> Multi puropose Chemical : Scale , Corroion Inhibitor And Dispersants</li>
<li>UNI-TREAT<sup>®</sup> Series Of On Line Cleaners</li>