Our complete systems available in one package, for reliable testing. These water testing kits are extremely simple and easy to use, based on standard and established analytical methods. These standards are based on methods approved by American Public Health Association (APHA), AWWA and different pharmacopoeias.
Parameter | Range | No. of Tests/Kit |
---|---|---|
Total Hardness | 2–40,5-100 mg/l as CaCO3 | 250 |
Total Hardness | 2–40,5-500 mg/l as CaCO3 | 250 |
Total Hardness | 5–100, 25–500mg/l as CaCO3 | 250 |
Total Hardness | 5–100, 25–500mg/l as CaCO3 | 250 |
Total Hardness | 1-20, 5-100mg/l as CaCO3 | 250 |
Total Hardness | 2-40, 5-100mg/l as CaCO3 | 500 |
Total Hardness | 2-40, 25-500mg/l as CaCO3 | 500 |
Total Hardness | 5–100, 25–500 mg/l as CaCO3 | 500 |
Total Hardness | 1–20, 5–100 mg/l as CaCO3 | 500 |
Calcium Hardness | 5–100 mg/l as CaCO3 | 300 |
Calcium Hardness | 25–500 mg/l as CaCO3 | 300 |
Chloride | 10–200 & 50–1000 mg/l as Chloride | 300 |
Chloride | 2–40, 5–100 mg/l as Chloride | 300 |
Alkalinity | 10–200 & 100–2000 mg/l as CaCO3 | 300 |
Alkalinity | 5–100 & 25–500 mg/l as CaCO3 | 300 |
Free Chlorine (DPD) | 0.1–2.0 mg/l as Chlorine | 200 |
Free Chlorine (DPD) | 0.2–4.0 mg/l as Chlorine | 200 |
Sulphite | 5–100 mg/l as Na2SO3 | 300 |
Nitrite (High Level) | 5–100 & 50–1000mg/l as NaNO2 | 300 |
Nitrite (Low Level) | 0.04–0.8mg/l as NO2 | 400 |
Dissolved Oxygen | 0.65–7.8 mg/l as Oxygen | 300 |
Chromate (Hexavalent) | 5–100 & 25–500 mg/l as Chromate | 200 |
Sulphate | 10–200 & 50–1000 mg/l as Sulphate | 350 |
Fluoride | 0.2–2.0 & 0.5–5.0 mg/l as Fluoride | 500 |
Fluoride | 1–20 mg/l as Fluoride | 500 |
Tannin (For Boiler Water) | 5–100 & 25–500 mg/l as Tannin | 300 |
Chlorine (Iodometric) | 10–200 mg/l as Chlorine | 300 |
Chlorine (Iodometric) | 1–20 mg/l as Chlorine | 300 |
Acidity | 10–200 & 100–2000 mg/l as CaCO3 | 300 |
Phosphonate / Sequestrant | 5–100 & 50–1000 mg/l as HEDP | 300 |
Phosphonate / Sequestrant | 2–40 & 5–100 mg/l as HEDP | 300 |
Amine (For Boiler Water) | 5–100 & 50–1000 mg/l as Cyclohexylamine | 300 |
Amine (For Boiler Water) | 1–20 mg/l as Cyclohexylamine | 300 |
Carbon Dioxide | 2-40 & 10-200 as CO2 | 300 |
Chlorine Dioxide | 0.2–4.0 mg/l as Chlorine Dioxide | 100 |
Hydrogen Peroxide | 5–100 & 50–1000 mg/l as H2O2 | 300 |
Orthophosphate (High Level) | 0, 5,10, 20, 30, 40 mg/l as PO4 | 100 |
Orthophosphate (Low Level) | 0.1, 0.2, 0.5, 1.0, 2.5, 5.0, 7.5,10 mg/l as PO4 | 500 |
Silica | 5, 10, 20, 40, 60, 80 mg/l as SiO2 | 100 |
Silica (Low level) | 0.01, 0.025, 0.05, 0.075, 0.1, mg/l as SiO2 | 75 |
Silica (Medium level) | 0.05, 0.1, 0.2, 0.4, 0.8, 1.5, 3.0, 5.0 mg/l as SiO2 | 100 |
Silica (High level) | 75, 100, 125, 150,175, 200 mg/l as SiO2 | 100 |
Iron (Low Level) | 0.05, 0.1, 0.3, 0.4, 0.7, 1.0, 1.5, 2.0 mg/l as Fe | 175 |
Iron (High Level) | 0, 2, 4, 6, 8, 10 mg/l as Fe | 175 |
Hydrazine | 0.1, 0.2, 0.3, 0.4, 0.5, 0.75 mg/l as Hydrazine | 200 |
Zinc | 0, 0.25, 0.5, 1.0, 2.0, 4.0 mg/l as Zn | 450 |
pH | 4 -10 | 500 |
Ammonium | 0.5, 1.0, 2.0, 4.0, 6.0, 8.0 mg/l as NH4 | 250 |
Ammonium | 0.05, 0.1, 0.25, 0.5, 0.75, 1.0 mg/l as NH4 | 100 |
Nitrate | 1.0, 2. 5 , 5, 7.5,10, 20, 30, 40,50 mg/l as NH3 | 400 |
Copper | 0, 0.5, 1.0, 1.5, 2.0, 2.5 mg/l as Copper | 250 |
Turbidity | 1, 5, 10, 20 NTU | - |
Molybdate | 5, 10, 20, 30, 40, 50 mg/l as MoO4 | 325 |
Chlorine (O. T. Method) | 0.05, 0.1, 0.2, 0.4, 0.7, 1.0 mg/l as Cl2 | 450 |
Chlorine (O. T. Method) | 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/l as Cl2 | 450 |
Chlorine (O. T. Method) | 0.2, 0.4, 0.7, 1.0, 2.0, 3.0 mg/l as Cl2 | 450 |
Chlorine (O. T. Method) | 0.1, 0.2, 0.5, 1.0, 1.5, 2.0 mg/l as Cl2 | 450 |